(1) No rotation of turbo blower
1. Unconnected Power Supply - Connected Power Supply
2. The motor does not work - check the connection of the motor or replace the motor
3. Damage of the head of the scroll turbo blower - repair or replacement of the turbo blower
4. The foreign body stuck in the scroll turbo blower - clearing the foreign body
(2) Increased noise
1. Dry Lubrication of Bearings - Adding Bearing Oil
2. Bearing damage - replacement of bearings
3. Impeller Wear - Replacement of Impeller or Pump Head
4. Rigidity or Shedding of Firmware-Tightening Firmware
5. Foreign bodies in the blower-clearing foreign bodies or replacing pump heads
(3) Increased vibration
1. Bearing damage - replacement of bearings
2. Impeller unbalance - clearing foreign body in impeller or calibrating dynamic and static balance
3. Spindle Deformation - Replacement of Spindle or Pump Head
4. Working state enters turbulent seismic zone - adjust working state to avoid turbulent seismic zone
5. Blockage of Inlet and Outlet Inlet and Filter Screen-Cleaning of Filter Screen
(4) Increase in temperature
1. High Inlet Temperature - Reducing Inlet Temperature
2. Dry Lubrication of Bearings - Adding Bearing Oil
3. Reduction of turbo blower Efficiency - Clearing Blade Dust or Replacing Pump Head
4. Change of working status - adjustment of working status
5. Increasing Environmental Temperature-Increasing Environmental Ventilation and Heat Dissipation
(5) Reduction of pressure
1. Decrease of Pump Head Speed-Low Power Voltage or Motor Failure
2. Increasing Resistance of Pipeline Network-Reducing Resistance of Pipeline Network
3. Change of working status - adjustment of working status
4. Motor Steering Reverse-Motor Rewiring
(6) Decrease of flow rate of vortex blower
1. Clogging of inlet and outlet gas filters-cleaning of filters
2. Decrease of Pump Head Speed-Low Power Voltage or Motor Failure
3. Increasing Resistance of Pipeline Network-Reducing Resistance of Pipeline Network
4. Increase of working state - adjust working state
5. Motor Steering Reverse-Motor Rewiring