High-pressure blowers are generally used on large-scale adsorption dryers, because large-scale adsorption dryers have a large amount of desiccant inside them. If the compressed air treatment desiccant is regenerated, not only does the compressed air waste be less than the user's requirements. And the air volume of compressed air does not meet the requirements of desiccant regeneration. Here, the high-pressure fan exerts its potential power, the flow and pressure are large, and the heater can be installed to meet the requirements of desiccant regeneration.
1. The fan needs to be cleaned during the installation and fixing process of the fan. If there is too much dust on the site, a filter bucket should be installed.
2. It is recommended to use proper fittings such as pipes and ball valves to prevent excessive pressure loss in the pipeline;
3. The customer reflects the problem of high temperature at the tuyere, and the PVC pipe is melted. It is recommended that the customer first install the 2-3 meter iron pipe and then install the PVC pipe;
4. Install a suitable pressure relief valve as appropriate to prevent overloading of the fan;
5. During the process of using the fan, pay attention to the heat dissipation and ventilation of the fan;
6. In order to reduce the noise of the fan, it is necessary to fix the installation base of the fan. The high-power fan must be fixedly mounted to prevent the fan from causing unnecessary bumps when the fan is too large.